FAN KIT INSTALLATION INSTRUCTIONS
IMPORTANT:
The fans are connected together, lift both fans out of the box at the same time to avoid possible
damage to the wires and/or connectors.
Note:
Millivolt board has been removed for clarity. It
is not necessary to remove the millivolt board
to install this optional fan kit.
1. Remove the lower grill if it has not been previously
removed.
2. Slide the left and right fans through the lower grill
opening (rt. side of the valve) pushing them all the
way to the back of the fireplace.
3. Slide the left fan assembly to the left until it stops
and slide the right fan assembly to the right until it
stops. NOTE: Each fan bracket is held in position by
a strip magnet attached to the bottom of each
bracket.
4. Install electrical box and mount the speed control on
a wall, if desired.
5. Remove the electrical panel on the left side of the
fireplace. Insert 115V wiring (with ground) through
the romex connector installed in the electrical box
and wire to the receptacle.
6. Secure receptacle into the electrical box.
7. Install the cover onto the electrical box and secure
with screws.
8. Replace the electrical panel and secure with screws.
9. Place the temperature control switch on the bottom
of the firebox.
10. Plug cord into receptacle in the electrical box.
11. Turn on/off speed control counter-clockwise until it
‘clicks’. This is the ‘OFF’ position.
12. Turn the speed control ‘ON’ by turning the know
clockwise past the ‘click’ - this is the highest setting.
NOTE:
The fan will not operate unless the speed control has been turned ‘ON’ and sufficient heat has been
applied to the temperature control switch. The fan will turn ‘ON’ and ‘OFF’ automatically when the
fireplace heats and cools. Adjust fan to desired speed while it is running.
NOTE:
This appliance must be electrically grounded and connected in accordance with local codes, or in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70-Current edition.
FIGURE 9A
FIGURE 9B
FIGURE 9C
Page 13