4. Burner won't light
Pilot not lit
Relight pilot
Regulator valve not turned “ON”.
Turn valve to "ON"
Rocker switch not turned “ON”.
Press bottom of switch.
Rocker switch wires not connected.
Check that wiring is connected.
Generator wires loose at
Reposition wire and tighten screws. See
regulator terminals
diagram below for wiring instructions.
Generator wire grounded out
Nuts securing millivolt board may need
due to pinching of wires
loosening to remove pinched wire.
Generator is not producing enough
Replace generator.
millivolts to operate burner.
Wall switch, remote control or
Connect properly or disconnect
thermostat not connected properly
and use on/off switch only.
or turned to wrong setting.
5. Burner won't stay lit
Generator wires loose on terminals.
Reposition wires and tighten screws
Generator wire grounded out
Nuts securing millivolt board may need
due to pinched wires.
loosening to remove pinched wire.
Generator is not producing enough
Check millivolt reading, replace
millivolts to sustain burner operation. generator if necessary.
Refractory panels not positioned
Secure refractory panels with
against firebox. high-temp
sealant,
especially
around the intake duct.
Generator
Piezo Wire
Generator Wire
ON/OFF Rocker
Switch Wire
ON/OFF Rocker
Switch Wire
Thermocouple connects
to back of valve
Pilot connects to
back of valve
Thermocouple
Piezo Ignitor
FIGURE 16
ATTENTION HOMEOWNER / INSTALLER:
1.
SLIGHTLY CLOSING THE VENTURI SHUTTER MAY BE NECESSARY IF FLAMES ARE BLUE. THIS IS LOCATED AT THE
END OF THE BURNER TUBE WHERE IS IT POSITIONED OVER THE ORIFICE. LOOSEN SET SCREW AND ADJUST.
RE-TIGHTEN SET SCREW.
BLUE FLAMES
AND/OR
LOW
FLAMES:
2.
SLIGHTLY ADJUSTING LOG POSITIONS MAY BE NECESSARY TO ACHIEVE OPTIMUM GLOW & FLAME APPEARANCE.
Page 26