TROUBLESHOOTING (55345-RF only)
BURNER WON‟T STAY LIT
A. Thermopile wires loose at valve terminals.
♦ Adjust if necessary.
B. Thermopile wires ground out due to pinched wires.
♦ Free pinched wires if necessary.
C
Refractory panel placement (if installed).
♦ Refractory panels must be tight against firebox walls. It may be necessary to secure panels with high
-temp sealant, especially around the
intake duct
.
A. No LP (propane) in tank.
♦ Check tank and refill if necessary.
B. Glass frame assembly not installed correctly
.
♦ Refer to page 15 in this manual for proper glass frame assembly installment instructions.
PILOT AND BURNER EXTINGUISH WHILE IN OPERATION
C. Improper pitch on horizontal vent.
♦ 1/4” (6 mm) rise per foot is required on horizontal venting.
D. Inner vent pipe leaking exhaust gases back into firebox.
♦ Check for leaks. Repair if necessary.
E. Improper vent cap installation.
♦ Check for proper vent cap installation. Maximum downward slope of horizontal vent cap is 1/4” (6 mm). Adjust if necessary.
♦ Check vent cap for blockage. Remove debris if necessary.
F. Excessive draft.
GLASS SOOTING
A. Improper log placement.
♦ Refer to log placement instructions on pages 33
-36 of this installation manual.
B. Improper venturi setting.
♦ Venturi may need to be opened slightly to allow more air into the gas mix.
C. Improper pitch on horizontal venting.
♦ 1/4” (6 mm) rise per foot is required on horizontal venting.