1. Place millivolt board in firebox, aligning the holes in the millivolt board with
holes in the firebox bottom. MAKE SURE SEALING GASKET IS IN PLACE
ON FIREBOX BOTTOM! Secure millivolt board to firebox bottom with the (8)
screws previously removed.
2. Place venturi spacers onto venturi mounting studs.
3. Re-install front burner assembly, making sure burner tube is positioned over
burner orifice. Secure with screws previously removed.
4. Reinstall back burner/log grate assembly by positioning burner tube into venturi
collar on millivolt board and pilot assembly through rectangular opening. Secure
front left and back right legs with screws previously removed.
5. Reinstall pilot shield.
6. Reinstall ember refractory.
7. Reinstall log set. (Pages 32-34).
8. Reconnect gas line to manual shut-off valve.
9.
Model 55345:
Reconnect any wall switch, remote control or thermostat wires to the top &
bottom terminals on the gas valve.
Model 55245-RF:
Re-connect the (2) wires to fan cord. Plug fan cord into receptacle.
10. Reinstall glass frame assembly. Page 15.
11. Reinstall upper louver & upper hood. Page 37.
12. Turn gas on.
13. Verify proper log placement, operation of fireplace, and any electrical
components.
WARNING: DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER THE MILLIVOLT BOARD) IN PLACE.
IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
CAUTION: CHECK ALL CONNECTIONS FOR LEAKS, WHETHER
FIELD OR FACTORY MADE.
MILLIVOLT BOARD INSTALLATION
PAGE 36
RE-CONNECT ANY REMOTE /
THERMOSTAT WIRES
INSTALL (8) SCREWS
INSTALL (2) SCREWS
INSTALL (2) SCREWS
BURNER LOG GRATE ASSEMBLY
PILOT SHIELD
FRONT BURNER ASSEMBLY
Содержание MINNETONKA 55345-RF
Страница 2: ......
Страница 4: ......
Страница 64: ......
Страница 65: ...PAGE 61...
Страница 66: ......
Страница 67: ...PAGE 62...