MILLIVOLT BOARD REMOVAL
1.
Models 55345 & 55345-RF:
Turn gas control knob to the
„OFF‟ position.
2. Shut off gas supply at the manual shut-off valve.
3. Disconnect gas line flex tube from the manual shut-off valve.
4.
Model 55345:
Disconnect any wall switch, remote control or thermostat wires
from top & bottom terminals on the gas valve.
Model 55345-RF:
Unplug fan cord from receptacle, disconnect the (2) wires from
fan cord. (Wires will remain connected to the back of gas valve).
5. Remove upper hood, upper louver. Page 37.
6. Remove glass assembly. Page 15.
7. Remove logs, pilot shield and ember log refractory.
8. Remove pilot shield.
9. Remove screws securing front left and back right log grate legs.
Remove burner/log grate assembly from firebox by lifting front
of burner assembly up out of flange while pushing pilot assembly
back slightly.
10. Remove screws securing front burner assembly. Remove front
burner assembly.
11. Remove adjustable venturi mounting spacers.
12. Remove (8) screws securing millivolt board. Lift board up and
out of firebox.
CAUTION: If the burner and/or pilot have been burning, use the appropriate protection to avoid burns or damage to personal property before
removing any components.
PAGE 35
BURNER LOG GRATE ASSEMBLY
REMOVE (8) SCREWS
PILOT SHIELD
FRONT BURNER ASSEMBLY
REMOVE (2) SCREWS
REMOVE (2) SCREWS