VENTING
#800-WPT WALL PASS-THRU
IMPORTANT: #800-WPT or #800-WPT2 WALL PASS-THRU MUST BE USED ON ALL HORIZONTAL VENT TERMINATIONS. THIS INCLUDES
BOTH INTERIOR AND EXTERIOR WALLS. FOLLOW INSTRUCTIONS BELOW.
TOP: 3” (76 mm) SIDES & BOTTOM: 1” (25 mm)
12-1/2” (318 mm) HIGH x 10-7/8” (276 mm) WIDE
IMPORTANT: If using the Kozy Heat series flexible vent system, remove the inner ring on
each wall thimble section with a tin snips. This will provide adequate room for the flexible
vent system.
A. Measure wall thickness; cut insulation panel (included) this length.
B. Install wall pass-
thru section marked #1 (with 3/8” (10 mm) flange) into framed opening. Secure to interior wall with screws (no
t provided).
C. From the exterior, place insulation between flange and top of framed opening in wall pass-thru section #1.
D. Install section marked #2 of wall pass-thru into framed opening, overlapping the metal sections as necessary to accommodate wall thickness.
Secure to exterior wall with screws (not provided).
HORIZONTAL TERMINATIONS CLEARANCES
FRAMING DIMENSIONS FOR #800-WPT KOZY HEAT WALL PASS-THRU
CUT RING OUT OF BOTH SECTIONS IF USING #800
SERIES FLEX VENTING.
INSULATION
HEAT SHIELD MUST BE FLUSH
WITH WALL PASS -THRU.
WARNING: MAINTAIN ALL CLEARANCES AS STATED IN THIS INSTALLATION MANUAL.
PAGE 22
3/8” (10 mm) FLANGE MUST BE
ON INSIDE WALL.