VENTING
(Flexible (#800 Series)
INSTALLATION OF #800 SERIES DIRECT VENT TERMINATION KIT(S)
IMPORTANT: The flex pipe is permanently attached to the exterior plate. DO NOT ATTACH #844 or #845 termination kit to
fireplace (or extension kit ) until it has passed through the wall. Install termination plates to outside wall exterior.
HORIZONTAL TERMINATIONS Refer to illustration on following page.
IF TERMINATING AGAINST VINYL SIDING, A VINYL SIDING PROTECTOR, INCLUDED WITH THE #844 AND #845 DIRECT
VENT KITS, MUST BE USED. FOLLOW INSTRUCTIONS INCLUDED.
CAUTION: This gas appliance must not be connected to a chimney flu serving another type of appliance.
1. If your vent system application does not require an extension kit, proceed to step #7.
2. If your vent system application will require one or more extension kits (Part #846), proceed with the following steps. Each #846 extension kit
contains enough 5” & 8” flexible aluminum to extend the chimney an additional 6‟ (1.83 m).
3.
Gently stretch 5” & 8” flexible aluminum pipes on the termination kit (#844 or #845) and on each extension kit (if used) the
length required
for your installation.
PAGE 28
NOTE: Page 26 has information on restrictor installation in conjunction with venting installation. Page 51 has information on
restrictor recommendations depending on burner flame appearance and instructions on installation after venting is completed.
IMPORTANT: The Kozy Heat wall pass-thru, part #800-WPT or #800-WPT2, must be used on all horizontal vent applications
regardless of which vent system you are using.
6. If additional extension kits are required, repeat steps #4 -
#5, placing 5” & 8” pipes onto the previous extension kit.
7.
With the spacer legs toward the wall, slide the interior firestop (H) over the 8” pipe and attach to the interior wall (over
wall materials).
IMPORTANT: DO NOT STRETCH EXTENSION KIT BEYOND 6‟ (1.83 m). DO NOT STRETCH BEYOND WHAT IS
REQUIRED - IT IS VERY DIFFICULT TO RECOMPRESS THE FLEX PIPES ONCE STRETCHED.
4.
Place a bead of sealant outside the 5” flex pipe collar (C) (the end with EXTERNAL lip), sliding it
inside
the 5” pipe on top of fireplace (D).
Secure with 3 evenly spaced screws.
5.
Place a bead of sealant inside the 8” flex pipe collar (E) (the end with the INTERNAL lip), sliding it
over
the 8” pipe on top of fireplace (F).
Secure with 3 evenly spaced screws.
NOTE: Attachment brackets are included with the termination kit. These optional brackets should be screwed or nailed (not
provided) onto the top and bottom of the 9-1/2” (241 mm) H x 9-1/2” (241 mm) W opening on the exterior of the house. The
termination plates then fit between these brackets. Using screws provided, secure brackets to the termination box (A). Attach
the vinyl siding protector (G).