FINALIZING THE INSTALLATION
RESTRICTOR USAGE:
Turn the fireplace on and allow to burn for 15 minutes. If flames indicate there is excessive draft (flickering, short flames) or insufficient draft
(lifting or ghosting flames) a restrictor may be necessary, or the previously installed restrictor may need to be modified or removed.
WARNING: TO AVOID PROPERTY DAMAGE OR PERSONAL INJURY, ALLOW FIREPLACE AMPLE TIME TO COOL BEFORE MAKING ANY
ADJUSTMENTS AND / OR INSTALLATIONS.
If it is determined that a restrictor is needed or restrictor modification is required after the termination is installed, access can be reached through
the fireplace baffle. Please remove logs, upper refractory clip and refractory to avoid damaging these components.
1. Remove the (4) screws securing baffle. Remove baffle to expose venting.
2. Depending on your specific needs, determined by the chart above along with other factors, make necessary modifications.
3. If installation of a restrictor (included in fireplace components packet) is necessary, bend tabs on restrictor to approx. 80 degree angles to
create tension when inserted into the exhaust pipe on fireplace. Insert restrictor into 5” exhaust pipe with tabs pointing to
wards you.
4.
If modification is necessary, remove restrictor by pulling it down and out of 5” exhaust pipe.
5. Reinstall baffle by resting baffle front above flange along inside top of firebox opening. Tip baffle back against rear firebox wall. Secure with
the (4) screws previously removed.
6. Reinstall refractory panels and log set.
7. Attach glass frame assembly and light fireplace. Wait 15 minutes before determining if any further modifications are necessary.
RESTRICTOR INSTALLATION / MODIFICATION
(after termination completion)
:
RESTRICTOR TROUBLESHOOTING
FLAME APPEARANCE
DRAFT PROBLEM
RESTRICTOR SOLUTION
Short, flickering
Excessive draft - not enough restriction
Add restrictor
Lifting or ghosting*
Insufficient draft - too much restriction
Remove inner ring (s) on restrictor or
remove restrictor
* Improper venting installation may cause flames to lift or “ghost”
- a dangerous situation. Inspect flames after installation to ensure proper
performance. If it is determined that the venting is correct and the restrictor has been removed, yet the flames are still lifting or ghosting, shut
off gas supply to fireplace and call a qualified service technician.
LARGE
5” EXHAUST
PAGE 51
FLANGE
Remove tab (s) to create small restrictor
Bend tabs to approx. 80 degree angles
to create tension to hold itself in place
when installed.
Slide restrictor into exhaust pipe at top of
fireplace with tabs pointing towards you.
(4) SCREWS SECURING BAFFLE
BAFFLE
Содержание MINNETONKA 55345-RF
Страница 2: ......
Страница 4: ......
Страница 64: ......
Страница 65: ...PAGE 61...
Страница 66: ......
Страница 67: ...PAGE 62...