#CLW-ST R.1 February 2021
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
FRAMING
17
3.5 Standard Installation
3.5.1 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material for Standard Installations
From appliance top stand-off brackets
0”
0mm
From appliance left and right stand-off brackets
0”
0mm
From appliance front
36”
914mm
Fireplace side finishing edge to adjacent sidewall
0”
0mm
Fireplace top finishing edge to 3/4” (19mm) mantel trim
8”
203mm
Mantel 6” (152mm) deep from fireplace top finishing edge
11-1/2”
292mm
Base of the fireplace to ceiling
76”
1930mm
Fireplace top finishing edge to ceiling
49-1/2”
1257mm
Figure 3.7, Clearance to Combustibles
For ease in maintaining clearances for horizontal
terminations, rotate studs flat at vent pass through
70
½
”
(1790mm)
64
½
”
(1638mm)
71”
(1803mm)
17”
(432mm)
64
½
”
(1638mm)
17”
(432mm)
Typical vertical installation
Typical horizontal installation
ALL DESIGN OPTIONS INSTALLATION
Nominal 2”x 4” framing used in enclosure framing