#CLW-ST R.1 February 2021
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
FRAMING
27
Figure 3.19, Single Opening Vented Cavity Crown Molding Installation
76”
(1930mm)
Min
Max
12”
(305mm)
3”
(76mm) Min
*must maintain 3” (76mm) clearance for full
length of crown molding/trim projection
Ceiling
Enclosure
Front View
Side View
SINGLE OPENING VENTED CAVITY INSTALLATION ONLY
Single Opening Vented Cavity Option (cont.)
•
Figure 3.19 shows the installation of crown molding or similar
trim work that goes up to the edge of the air discharge opening.
12” (305mm) is the maximum length of the molding or trim
projection and you must maintain 3” (76mm) clearance for the
full length of crown molding/trim projection. This molding or
trim cannot decrease the minimum opening requirement.