![kozy heat BELLINGHAM 38 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/kozy-heat/bellingham-38/bellingham-38_installation-and-operation-manual_1999711064.webp)
Setup Proflame 2 IFC Module–Backup Battery Operation
SECTION 10
OPERATING INSTRUCTIONS
#BHM-38 & #BHM-38-BW
R.1 September 2021
64
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
10.1 Setup Proflame 2 IFC Module
1. Set the main ON/OFF rocker switch in the OFF position.
2. Install (4) AA batteries (not included) into backup battery holder
on the control module.
3. Install (3) AAA batteries (included in the components packet) in
the remote control battery bay, located at the base of the remote.
4. Connect the IFC Module to an AC power supply.
10.2 Initialize the Control System
IMPORTANT: Remove all packaging and combustible material from the
firebox before initializing the control system.
NOTE: Performing the next steps will initiate pilot start-up in manual
mode, where the pilot igniter will spark repeatedly. The pilot will ignite
if gas is supplied to the fireplace.
1. To access the ON/OFF toggle switch and remote learn button on
the left side of the unit, remove the safety barrier screen by lifting
up and out of its slots.
2. Locate the remote sync button on the control module access
switch on the left side of the fireplace. See
FIGURE 10.1
below.
3. Press the remote sync button. The IFC module will BEEP (3) times
and illuminate an amber LED. This indicates the receiver is ready
to synchronize with the transmitter.
4. Within (5) seconds, push the ON/OFF button on the remote
control. The receiver will BEEP (4) times to indicate the
transmitter’s command is accepted, and is set to the transmitter’s
particular code. The pilot will automatically ignite.
5. Press the remote control ON/OFF button again. The pilot will
extinguish, confirming the remote control command. The control
system is now initialized.
6. Set the main ON/OFF toggle switch to ON position for remote
control operation of the main burner and fireplace features.
7. Reinstall safety barrier screen.
10.3 Reset the System for
Manual Operation
1. Access the toggle switch and remote learn button on the left side
of the unit by removing the safety barrier screen by lifting up and
out of its slots.
2. Set the ON/OFF rocker switch to OFF position.
3. Press and hold the remote sync button until it emits (3) beeps and
an amber LED is illuminated.
4. Within (5) seconds, press the remote sync button again. This
will close synchronization with the remote control. The pilot will
automatically light.
•
Turn the main burner ON by setting the ON/OFF switch in ON
position. The main burner will only operate on HI.
•
Turn the main burner OFF by setting the ON/OFF switch in the
OFF position. The pilot will remain lit even if burner is turned off,
provided CPI mode is turned on.
10.4 Automatic Safety Restart
•
This system will execute an automatic turn OFF command for
approximately (5) seconds within (24) hours of a continued pilot
flame ignition to perform a safety check. This allows the system to
verify correct safety functions.
•
After the turn OFF sequence is completed, the IFC module will re-
execute the latest command.
10.5 Backup Battery Operation
This appliance will operate on the backup battery pack when electric
power is interrupted, or in a power outage. The lifespan of the backup
batteries depend on various factors, such as the quality of the batteries,
number of ignitions, et cetera.
•
When the backup battery pack is low, the IFC module will emit a
double-beep while receiving an ON/OFF command.
•
No commands will be accepted after this alert until the back up
batteries are replaced.
•
Once replaced, the IFC module will emit a ‘beep’ as soon as it is
powered.
Remote learn button
ON/OFF toggle switch
FIGURE 10.1
ON/OFF Toggle Switch and Remote Learn Button Location