Vented Cavity–Top Vented Cavity
SECTION 3
FRAMING
#BHM-38 & #BHM-38-BW
R.1 September 2021
29
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
3.8.3 Top Vented Cavity Option
WARNING: Enclosure measurements must maintain minimum
framing specs as outlined in section
3.5, ROUGH FRAMING
(page
15). Minimum dimensions for the air discharge opening MUST BE
maintained after all finishing materials are installed.
NOTE: The top vented cavity option allows the use of 19 gauge (or less)
1/2” x 1/2” hardware mesh to prevent any items from entering the
vented cavity. This hardware mesh is optional and the ONLY approved
item for use within the air discharge opening.
WARNING: Do NOT cover or place any items in the air discharge
opening area. Grilles and louvers are NOT allowed.
WARNING: Failure to comply with these instructions could create
a fire hazard. Ensure air flow within the air discharge opening is not
restricted in any way.
These are minimum dimensions shown for the air discharge
opening, and the opening may be increased, if desired, as long as all
requirements are followed. It is recommended to limit your opening
for aesthetic purposes and to avoid items falling into the enclosure.
•
FIGURE 3.21
shows the minimum 1-1/2” (38mm) clearance from
the fireplace enclosure top to the ceiling in all three sides of the
enclosure.
1
½
”
(38mm)
1
½
”
(38mm)
1
½
”
(38mm)
Top vented cavity air discharge in all three sides of fireplace enclosure
FIGURE 3.21
Top Vented Cavity Installation
TOP VENTED CAVITY INSTALLATION