Panel Installation
SECTION 8
FIREPLACE SETUP
#BHM-38 & #BHM-38-BW
R.1 September 2021
54
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
8.3 Panel Installation
WARNING: RISK OF FIRE! Do not operate this fireplace without a
refractory or black glass panel kit installed.
•
Refractory or black glass panels will provide insulation and are
required to operate this fireplace.
•
If converting to propane, complete the conversion before
installing any refractory or black glass panels. Follow instructions
included with the kit.
BEFORE INSTALLATION:
1. Remove the safety barrier screen, glass assembly, and log set (if
installed).
2. Locate the (2) screw holes in the rear of the fireplace baffle and
the (2) screw holes located on each side of the fireplace baffle.
Locate the (4) panel clips shipped with the panels. These clips are
shipped flat. Separate the clips at the perforations and bend the
metal finger at a 90° angle.
8.3.1 Refractory Panels
1. Install back refractory panel. Secure with panel clips previously
bent. See
FIGURE 8.3
.
2. Install side refractory panels. Secure with (2) panel clips for each
side with provided screws. See
FIGURE 8.4
.
8.3.2 Black Glass Panels
NOTE: The smooth side of the glass panel will face forward in the
firebox, with the textured side against the firebox walls.
It is recommended to wear clean gloves when handling panels. Handle
with care. Use both hands when installing.
1. Install back black glass panel. Secure with panel clips previously
bent with provided screws. Verify black glass is flat against the
firebox.
2. Install side black glass panels. Carefully slide the panel on the
main log support until you reach the back of firebox as shown in
FIGURE 8.5
.
3. Secure side panels with refractory clips previously bent. Verify
black glass is flat against firebox.
FIGURE 8.5
Side Black Glass Panels Installed
FIGURE 8.4
Side Refractory Panel Installed
FIGURE 8.3
Back Refractory Panel Installed