Heat Management Preparation Overview
SECTION 3
FRAMING
#BHM-38 & #BHM-38-BW
R.1 September 2021
21
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
3.7.2 Vented Cavity and Komfort Zone Kits
The vented cavity design options and Komfort Zone Kits have specific
framing requirements, mantel requirements, and exterior trim
dimensions.
•
All framing requirements in section
3.5, ROUGH FRAMING
will
apply to all vented cavity and Komfort Zone Kit installations.
•
All minimum required dimensions must be maintained after all
finishing materials are installed.
•
The appliance convection baffle and outer shell plates must
be removed for heat distribution required vented cavity
framing designs and Komfort Zone Kit installations, as shown in
FIGURE 3.11
.
1. Remove the (2) top cover plates, (4) screws each. See
FIGURE 3.12
.
2. Remove convection baffle. The baffle is secured by the baffle clip
by (2) screws located in the front center, and (2) screws behind
the upper edge of the fireplace opening. See
FIGURE 3.12
.
Recycle this panel as it is no longer needed.
Convection airflow
with
baffle and cover
plates removed
Convection airflow
with
baffle in place
Convection
baffle
to be
removed
Komfort Zone Kit installations and vented cavity options
must remove (2) top cover plates and convection baffle
Baffle clip
Top cover plates
Convection Baffle
FIGURE 3.11
Air Flow inside Appliance
FIGURE 3.12