30
FIREPLACE SETUP
8.3 #B36-500 Log Set Installation
CAUTION: Do not place logs directly over burner port holes.
Improper log placement may affect flame appearance and
cause excessive soot to build upon the logs and glass.
• If converting to LP (propane) gas, complete the conversion
before installing the log set. Follow the conversion
instructions included with the kit.
• Log numbers are located on the bottom of each log. Refer
to the following instructions and illustrations for proper log
placement.
1. Position the ember panel in front of the burner.
2. Align the holes in the bottom of base logs (B36-1 to B36-4)
with the mounting pins on the burner. Push logs down onto
pins to seat.
3. Align logs B36-5 and B36-6 with the notches on base logs.
4. Align log B36-7 with the bracket on the burner and the notch
on ember panel.
5. Distribute rockwoll embers onto the logs and burner using a
stiff bristle brush.
Figure 8.2, Mounting Pin Locations
Figure 8.3, Base Logs
Figure 8.4, Logs B36-5, B36-6, and B36-7