FIREPLACE SETUP
31
8.4 Control Board Removal
and Installation
WARNING: If burner and/or pilot have been burning,
use appropriate protection to avoid burns or damage
to personal property before removing any components.
DO NOT OPERATE THIS APPLIANCE WITHOUT THE SEALING
GASKET (LOCATED UNDER THE CONTROL BOARD) IN PLACE.
IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
CAUTION: Check all connections for leaks with soapy water,
whether field or factory made.
8.4.1 Control Board Removal
1. Turn the fireplace off.
2. Remove the safety barrier.
3. Locate the manual valve installed by your qualified service
technician.
4. Turn the manual valve clockwise to the OFF position.
5. Disconnect any wall switch, remote control, or thermostat
from the top and bottom terminals on the gas valve, OR
unplug all components from receptacle and disconnect all
wiring harnesses attached to the gas valve.
6. Remove the glass frame assembly and log set.
7. Remove back log plate (3) screws.
8. Remove burner assembly, (2) screws on each side.
9. Remove the burner heat shield (3) screws, located at the
back of the firebox.
10. Remove and save (8) screws securing the control board.
11. Lift the control board out of the firebox, being careful not to
damage the sealing gasket underneath.
8.4.2 Control Board Installation
1. Place the control board in the firebox, aligning the holes in
control board with the holes in firebox bottom.
VERIFY SEALING GASKET IS IN PLACE.
2. Secure the control board to the firebox using (8) screws
previously removed.
3. Reinstall the burner heat shield (3) screws.
4. Reinstall burner assembly (2) screws.
5. Reinstall back log plate (3) screws.
6. Reinstall log set.
7. Reconnect any wall switch, remote control, or thermostat
wires to the top and bottom terminals on the gas valve, OR
reconnect all wiring harnesses to the gas valve. Plug all
components into an electrical outlet.
8. Reinstall the glass frame assembly and safety barrier.
9. Turn the manual valve counter clockwise to the ON position.
10. Verify proper log placement, operation of fireplace, and any
electrical components.
Figure 8.5, Control Board Removal and Installation