1.1  Appliance Certification

Laboratory:

 OMNI-Test Laboratories in Portland, Oregon 

Standards: 

•  ANSI Z21.88-2014/CSA 2.33-2014, 

Vented Gas Fireplace 

Heaters

•  CGA 2.17-M91 (R2009), 

Gas-Fired Appliances for Use at High 

Altitudes

•  CSA P.4.1-2009, 

Testing Method for Measuring Annual 

Fireplace Efficiency

This installation must conform with local codes, or in the absence 
of local codes, with the 

National Fuel Gas Code, ANSI Z223.1/

NFPA 54, or the 

Natural Gas and Propane Installation Code, CSA 

B149.1.

1.2  Requirements for the 

Commonwealth of Massachusetts

The following requirements reference various Massachusetts 
and national codes not contained in this manual.

For all sidewall horizontally vented gas fueled equipment installed 
in every dwelling, building or structure used in whole or in part for 
residential purposes, including those owned or operated by the 
Commonwealth and where the side wall exhaust vent termination 
is less than (7) feet above finished grade in the area of the venting, 
including but not limited to decks and porches, the following 
requirements shall be satisfied:

1.2.1  Installation of Carbon 

Monoxide Detectors

At time of installation of side wall horizontally vented gas fueled 
equipment, the installing plumber or gas-fitter shall observe that 
a hard wired carbon monoxide detector with an alarm and battery 
back-up is installed on the floor level where the gas equipment is 
to be installed. In addition, the installing plumber or gas-fitter shall 
observe that a battery operated or hard wired carbon monoxide 
detector is installed on each additional level of the dwelling, 
building or structure served by the side wall horizontal vented 
gas fueled equipment. It shall be the responsibility of the property 
owner to secure the services of qualified licensed professionals for 
the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled 
equipment is installed in a crawl space or attic, the hard wired 
carbon monoxide detector with alarm and battery back-up may 
be installed on the next adjacent floor level. In the event that 
the requirements of this subdivision can not be met at the time 
of completion of installation, the owner shall have a period of 
thirty (30) days to comply with the above requirements; provided, 
however, that during said thirty (30) day period, a battery operated 
carbon monoxide detector with an alarm shall be installed.

1.2.2  Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance with 
the above provisions shall comply with NFPA 720 and be ANSI/UL 
2034 listed and IAS certified.

1.2.3  Signage

A metal or plastic identification plate shall be permanently mounted 
to the exterior of the building at a minimum of eight (8) feet 
above grade directly in line with the exhaust vent terminal for the 
horizontally vented gas fueled heating appliance or equipment. The 

sign shall read, in print no less the one-half inch (½) in size, “GAS 
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. 

1.2.4  Inspection

The state or local gas inspector of the side wall horizontally 
vented gas fueled equipment shall not approve the installation 
unless, upon inspection, the inspector observes carbon monoxide 
detectors and signage installed in accordance with the provisions 
of 248 CMR 5.08 (2) (a) 1 through 4.

1.2.5  Exemptions

The following equipment is exempt from 248 CMR 5.08 (2) (a) 1 
through 4: The equipment listed in Chapter 10 entitled “Equipment 
Not Required To Be Vented” in the most current edition of NFPA 
54 as adopted by the Board; and Product Approved side wall 
horizontally vented gas fueled equipment installed in a room or 
structure separate from the dwelling, building or structure used in 
whole or in part for residential purposes.

1.2.6  Manufacturer Requirements

1.2.6.1  Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally 
vented gas equipment provides a venting system design or venting 
system components with the equipment, the instructions provided 
by the manufacturer for installation of the equipment and the 
venting system shall include:

•  Detailed instructions for the installation of the venting system 

design or the venting system components; and

•  A complete parts list for the venting system design or venting 

system.

1.2.6.2  Gas Equipment Venting 

System NOT Provided

When the manufacturer of Product Approved side wall horizontally 
vented gas equipment does not provide the parts for venting the 
flue gases, but identifies “special venting systems”, the following 
requirements shall be satisfied by the manufacturer:

•  The referenced “special venting systems” instructions shall 

be included with the appliance or equipment installation 
instructions and;

•  The “special venting systems” shall be Product Approved by 

the Board, and the instructions for that system shall include a 
parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved 
side wall horizontally vented gas fueled equipment, all venting 
instructions, all parts lists for venting instructions, and/or all venting 
design instructions shall remain with the appliance or equipment at 
the completion of the installation.

1.0  INTRODUCTION

Содержание BAY-36-MV

Страница 1: ...ed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate...

Страница 2: ......

Страница 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Страница 4: ......

Страница 5: ...18 6 2 Minimum Termination Clearances 19 7 0 VENTING 20 7 1 Rear Vent Conversion Instructions 20 7 2 Venting Requirements 22 7 3 Approved 4 x 6 Vent Systems 22 7 4 Vent Clearances 22 7 5 Use of Elbow...

Страница 6: ...accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the...

Страница 7: ...a 6 4 WC 1 59 kPa Orifice Size DMS 42 53 2 2 1 Altitude Adjustment This appliance may be installed at higher altitudes Please refer to National Fuel Gas Code ANSI Z223 1 NFPA 54 CSA B149 1 Natural Gas...

Страница 8: ...to Rear Vent Center Inches 32 35 3 4 18 7 8 15 13 16 32 5 8 26 13 16 10 7 7 8 25 7 8 Millimeters 813 907 479 401 829 681 254 199 657 18 7 8 479mm 7 7 8 199mm 15 13 16 401mm 10 254mm 26 13 16 681mm 32...

Страница 9: ...ptions TOP AND SIDES OVERLAP NO OVERLAP INSIDE FIT TOP AND SIDES OVERLAP TOP AND SIDES OVERLAP TOP AND SIDES OVERLAP TOP AND SIDES OVERLAP TOP AND SIDES OVERLAP B36 PSF B36 FRSF B36R MSF B36A MSF B36R...

Страница 10: ...top stand offs provide the 10 in 254 mm minimum clearance to the header Use only non combustible material in this area for the entire width of the fireplace DO NOT use wood sheetrock et cetera in thi...

Страница 11: ...chamber Provide adequate clearance in front of the fireplace for barrier removal component access gas line installation service access et cetera Framing dimensions should allow for wall covering thic...

Страница 12: ...codes Outside walls should be insulated to prevent cold air from entering room Follow vent pipe manufacturer s installation instructions for vertical terminations A minimum of 1 in 25 mm clearance on...

Страница 13: ...TYPICAL CORNER INSTALLATION TOP VENT TYPICAL HORIZONTAL INSTALLATION REAR VENT 36 920mm 1 25mm 15 7 8 403mm INCLUDES TYPICAL FINISH MATERIAL WITH FLUSH MOUNT 36 920mm 26 673mm 1 25mm TYPICAL VERTICAL...

Страница 14: ...g away from the fireplace 3 Secure the nailing flanges to the fireplace with screws provided through the slots in nailing flanges 4 Bend perforation on nailing flange until parallel with fireplace fac...

Страница 15: ...FACING AND FINISHING 15 4 2 Mantel Requirements 13 343mm 15 394mm 17 445mm 14 356mm 12 305mm 9 229mm 13mm NON COMBUSTIBLE MATERIAL ONLY FIREPLACE ENCLOSURE FLOOR 45 1156mm SINGLE VERTICAL HEADER...

Страница 16: ...screen front until the notched tabs are firmly in position verifying the depth accommodates finish material To remove safety screen lift the screen up and out of slots 4 3 3 Overlap Fit Direct Mount...

Страница 17: ...Pa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A listed and Commonwealth of Ma...

Страница 18: ...2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27 Over 20 12 to 2...

Страница 19: ...ce 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachusetts 10 ft 3 m L Clearance above paved sidewalk or paved dri...

Страница 20: ...ctions below to be used NOTE All components removed from the top vent exit will be reinstalled for the rear vent 7 1 1 Remove Top Vent Collars 1 REMOVE 7 SCREWS SECURING COVER PLATE 2 REMOVE 4 SCREWS...

Страница 21: ...GASKET IS IN PLACE UNDERNEATH SECURE WITH 6 SCREWS PREVIOUSLY REMOVED 2 INSTALL 6 168mm COMBUSTION AIR INTAKE COLLAR TO REAR VERIFY GASKET IS IN PLACE SECURE WITH 4 SCREWS PREVIOUSLY REMOVED 3 SECURE...

Страница 22: ...imney Horizontal Vertical Selkirk Direct Temp Horizontal Vertical Simpson DuraVent DirectVent Pro EXCEPT Snorkel 46DVASNK14 Horizontal Vertical 7 4 Vent Clearances NOTE Wall thimble products that comp...

Страница 23: ...tion Venting Table 7 4 NG LPG Minimum Vertical Maximum Horizontal Minimum Vertical Venting Minimum Horizontal Run Maximum Horizontal Run 90 elbow off appliance top 6 in 152 m 8 ft 2 4 m Table 7 5 NG L...

Страница 24: ...corresponding screw holes located in front of the flue outlet on the top of the fireplace 3 Secure the vertical vent heat shield to the fireplace with 2 attachment screws provided in the components p...

Страница 25: ...l to Vertical Venting Minimum Vertical Length Maximum Vertical Length 90 elbow off appliance back 3 ft 914 mm 50 ft 15 2 m Table 7 8 NG Max Vertical Max Horizontal Combination Maximum Vertical Rise Ma...

Страница 26: ...rtical Venting Minimum Vertical Length Maximum Vertical Length 90 elbow off appliance back 3 ft 914 mm 50 ft 15 2 m Table 7 11 LPG Max Vertical Max Horizontal Combination Maximum Vertical Rise Maximum...

Страница 27: ...25 mm top clearance and 1 in 25 mm side clearance to the exterior wall and seal OPTIONAL insulate the wall thimble with any unfaced insulation products listed as non combustible per ASTM E 136 3 Apply...

Страница 28: ...ith a receptacle box cover assembly in the fireplace components packet Kit Components 1 133 CFM fan with temperature control switch 1 Remove the safety barrier safety barrier and log set 2 Remove burn...

Страница 29: ...G WIRING 110 120 V 60 Hz LEGEND A Black hot from incoming line B Black from speed control C White neutral from incoming line D White neutral from receptacle E Ground bare from incoming line F Ground g...

Страница 30: ...e bottom of each log Refer to the following instructions and illustrations for proper log placement 1 Position the ember panel in front of the burner 2 Align the holes in the bottom of base logs B36 1...

Страница 31: ...crews 8 Remove burner assembly 2 screws on each side 9 Remove the burner heat shield 3 screws located at the back of the firebox 10 Remove and save 8 screws securing the control board 11 Lift the cont...

Страница 32: ...115V wire to the gas valve If desired a thermostat a wall switch or a remote control assembly may be installed to enable ON OFF control of the main burner Only one of these components may be installed...

Страница 33: ...nd any gas control that has been under water LIGHTING INSTRUCTIONS 1 STOP Read all the safety information above on this page 2 Set thermostat to lowest setting if applicable 3 Turn off all electric po...

Страница 34: ...s near maximum inlet pressure 6 Press the rocker switch to OFF 7 Turn the gas control knob to OFF 8 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snu...

Страница 35: ...f soot is present on the glass check log positioning before adjusting the venturi Logs must not block burner ports 1 Remove the safety barrier and glass frame assembly 2 Remove the log set the back lo...

Страница 36: ...ualified service technician If it is determined that a restrictor is needed or restrictor modification is required after the vent termination is installed access can be reached by removing the firepla...

Страница 37: ...roper flame impingement Loose thermocouple connection Ensure thermocouple connection at gas valve is full inserted and tight hand tight plus 1 4 turn Thermocouple reading below 15 millivolts Disconnec...

Страница 38: ...panels with high temperature sealant especially around the intake duct Pilot and burner extinguish while in operation No LP gas in tank Check LP propane tank Refill if necessary Incorrect glass frame...

Страница 39: ...e Person Frequency Every 6 months Action Disconnect the fans from electrical current and vacuum The bearings are sealed and require no oiling 13 3 Vent System NOTE If the vent air intake system is dis...

Страница 40: ...0 Conversion Kit NG OCK S42A Flexible Pilot Tubing valve to pilot 700 099 Conversion Kit LPG OCK S53A Millivolt Generator 700 092 Log Plate B36L 351 Thermocouple 700 093 SAFETY BARRIERS Full Rectangul...

Страница 41: ...ssong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole oblig...

Страница 42: ......

Страница 43: ...f the defective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective...

Отзывы: