![kozy heat BAY-36-MV Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/kozy-heat/bay-36-mv/bay-36-mv_installation-and-operation-manual_1999706013.webp)
FRAMING
13
3.6 Clearances to Combustibles
36 ¼”
(920mm)
1”
(25mm)
TYPICAL HORIZONTAL INSTALLATION
TOP VENT
15 7⁄8”
(403mm)*
*INCLUDES ½” TYPICAL FINISH MATERIAL WITH FLUSH MOUNT
36 ¼”
(920mm)
15 7⁄8”
(403mm)*
1”
(25mm)
TYPICAL VERTICAL INSTALLATION
TOP VENT
*INCLUDES ½” TYPICAL FINISH MATERIAL WITH FLUSH MOUNT
50 7⁄16”
(1280mm)
36 ¼”
(920mm)
11 7⁄8”
(301mm)
¼”
(6mm)
24 11⁄16”
(628mm)
35 5⁄8”
(905mm)
TYPICAL CORNER INSTALLATION
TOP VENT
TYPICAL HORIZONTAL INSTALLATION
REAR VENT
36 ¼”
(920mm)
1”
(25mm)
15 7⁄8”
(403mm)*
*INCLUDES ½” TYPICAL FINISH MATERIAL WITH FLUSH MOUNT
36 ¼”
(920mm)
26½”
(673mm)*
1”
(25mm)
TYPICAL VERTICAL INSTALLATION
REAR VENT
*DIMENSION SHOWN WITH LISTED DURAVENT ELBOW.
NOTE: Approved vent system elbows for this appliance vary in vertical length. Consult
vent manufacturer’s instructions to determine the elbow dimension used for your
installation. Adjust as necessary to maintain the required 1” (25mm) clearance from the
vent pipe to combustible material.