VENTING
21
7.1.2 Install Exhaust and Combustion Air
Intake Collars to Fireplace Rear
7.1.3 Install Cover Plates to Fireplace Top
WARNING: The cover plates must be installed on the top of the
fireplace. DO NOT proceed with the fireplace installation until
the vent conversion is completed.
1
INSTALL 4” (101mm) EXHAUST COLLAR TO REAR.
VERIFY GASKET IS IN PLACE UNDERNEATH.
SECURE WITH (6) SCREWS PREVIOUSLY REMOVED.
2
INSTALL 6⅝” (168mm) COMBUSTION AIR INTAKE COLLAR
TO REAR. VERIFY GASKET IS IN PLACE.
SECURE WITH (4) SCREWS PREVIOUSLY REMOVED.
3
SECURE COVER PLATE WITH (5) SCREWS
PREVIOUSLY REMOVED
1
INSTALL EXHUAST COVER PLATE TO FIREPLACE TOP.
VERIFY GASKET IS IN PLACE.
SECURE WITH (6) SCREWS PREVIOUSLY REMOVED.
2
INSTALL COMBUSTION AIR INTAKE COVER PLATE TO AIR
CHUTE. VERIFY GASKET IS IN PLACE.
SECURE WITH (4) SCREWS PREVIOUSLY REMOVED.
3
SECURE COVER PLATE WITH (7) SCREWS
PREVIOUSLY REMOVED.