FIREPLACE SETUP
8.0 FIREPLACE SETUP
8.1 Glass Frame Assembly
WARNING: Do not operate this fireplace with the glass removed,
cracked, or broken. Replacement of the glass assembly, should
be done by a licensed or qualified service person.
8.1.1 Remove Glass Frame Assembly
WARNING: Do not remove the glass assembly when hot.
1. Locate (2) spring-loaded latches securing the glass assembly
at the bottom of the firebox.
2. Pull the spring-loaded latches out and down to release the
bottom of the glass assembly.
3. Life glass assembly up and off of the (2) tabs located at the
top of the firebox.
8.1.2 Install Glass Frame Assembly
1. Align the slots on top of the glass assembly over the tabs at
the top of the firebox while lowering the bottom of the glass
assembly into position.
2. Pull the spring-loaded latches out and up to secure the
bottom of glass to the bottom of the fireplace.
8.2 #B36-028 Optional Fan Kit
WARNING - Electrical Grounding Instructions: This appliance
is equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
WARNING: Installation of this fan kit should be done by a
qualified installer. Verify household breaker is shut off prior to
working on any electrical lines.
NOTE: It easier to install the fan kit before connecting the gas
line to the control board.
• This appliance, when installed, must be electrically grounded
in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
• Code-approved line voltage wiring, 14 gauge or better,
must be used when wiring this assembly. Refer to your local
electrical codes for specific requirements.
• A pre-installed electrical box is included with the appliance,
along with a receptacle/box cover assembly in the fireplace
components packet.
Kit Components: (1) 133 CFM fan with temperature control switch
1. Remove the safety barrier, safety barrier, and log set.
2. Remove burner assembly (2) screws, and the pilot shield.
3. Remove the burner heat shield (2) screws, located at the
back of the firebox.
4. Remove (8) screws securing the control board. Lift board out
of the firebox.
5. Insert the fan through the opening and position at the back of
the firebox. Secure with (2) flange nuts.
6. Reinstall the control board. Secure with (8) screws previously
removed.
7. Insert 110-120V wiring (with ground) through romex
connector and wire to speed control / receptacle assembly
matching black (hot) white (neutral) and green (ground)
wires to corresponding wires on speed control / receptacle
assembly. See Figure 8.1.
8. Secure speed control/receptacle assembly to electrical box
with (2) screws provided in the fireplace components packet.
9. Reinstall electrical access panel. Tighten screw.
10. Attach the temperature control switch to the bottom of the
firebox.
11. Plug fan cord into the electrical box receptacle.
12. Turn speed control counter-clockwise until it ‘clicks’. This is
the OFF position.
Turn speed control ON by turning knob clockwise past the
‘click’ - this is the highest setting.
13. Reinstall all components previously removed.
IMPORTANT: This fan will not operate unless speed control
has been turned ON and sufficient heat has been applied to
temperature control switch. The fan will turn ON and OFF
automatically as fireplace heats and cools. Adjust fan to desired
speed while it is running.
TEMPERATURE CONTROL SWITCH POSITION
Before adjusting temperature control switch, unplug 3-prong plug on
fan cord from receptacle.
Adjust position of temperature control switch to a warmer location
under firebox to turn fan ON sooner or move it to a cooler location
under firebox to turn fan ON later. The fan will turn on when sensor
in temperature control switch reaches 110° F and will turn OFF when
sensor reaches 90° F.
After adjustment, plug 3-prong plug on fan cord into receptacle.