32
THERMOSTAT, WALL SWITCH, REMOTE
9.2 Remote Control
• Follow instructions included with the remote control.
• The insulated cover included with the remote control must be
in place over the remote receiver to prevent overheating.
9.3 Thermostat and Wall Switch
NOTE: Installation of the thermostat or wall switch should only
be performed by a qualified installer.
1. Run low-voltage wires from the terminals on the gas valve
to the desired location of the component (thermostat or wall
switch).
2. Attach the appropriate connectors to the wall switch wires
or thermostat wires. Connect to top and bottom terminals
marked TH and TP-TH on the gas valve.
NOTE: The fireplace must be turned ON and OFF by the same
method. For example, if the fireplace insert is turned on by the
remote control, it must be turned off by the remote control.
CAUTION: Do connect high voltage (115V) wire to the gas valve
If desired, a thermostat, a wall switch, or a remote control assembly
may be installed to enable ON/OFF control of the main burner.
Only one of these components may be installed. Follow instructions
included with your chosen assembly.
9.1 Rocker Switch Operation
• It is optional to disable the rocker switch operation of the
main burner by disconnecting the rocker switch wires from
the back of the gas valve.
• If the rocker switch wires are not disconnected, the ON/
OFF rocker switch on the millivolt board must be in the OFF
position for proper operation of the thermostat, wall switch, or
remote control.
• If the rocker switch is ON, the main burner will operate until
it is turned OFF by the rocker switch. These components will
not turn the main burner OFF when it has been turned ON by
the rocker switch.
9.0 THERMOSTAT, WALL SWITCH, REMOTE
ON/OFF ROCKER
SWITCH WIRES
BAT. LOW
50
60
70
80
90
50
60
70
80
90
Figure 9.1, Rocker Switch Wire Locations (Side View)
Figure 9.2, Remote Control Wiring Diagram
Figure 9.3, Thermostat Wiring Diagram