![Kontron KBox C-102 Series Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/kontron/kbox-c-102-series/kbox-c-102-series_user-manual_1996284087.webp)
KBox C-102 - User Guide, Rev. 1.0
// 87
Sub-Screen
Function
Second level Sub-Screen / Description
H/W Monitor>
(continued)
Carrier
Temerature>
Read only field
Displays carrier temperature in °C
External Fan-
Fan Control>
Sets Fan Control mode for external fan
Disabled - stops the fan
Manual – manually set the fan
Auto - hardware monitor controls cooling, similar to ACPI based ‘Active
Cooling’, without producing a software load to the system.
[Disable, Manual, Auto]
External Fan–
Fan Pulse>
Displays number of pulse fan produces during 1 revolution (Range: 1-4)
[2]
External Fan-
Fan Trip point>
Displays temperature at which fan accelerates. (Range: 20°C to 80°C)
[50]
External Fan-
Trip Point
Speed>
Displays Fan speed at trip point in %. Minimum value is 30%
Fan always runs at 100% at TJmax (-10°C)
[30]
External Fan
Reference
Temperature>
Determines temperature source used for automatic fan control
[PCH Temperature, Module Temperature, CPU Temperature]
Additional information External Fan
An external fan can be connected to baseboard. The external fan’s control lines are routed via
the COMe connector.
5.0V Standby>
Read only field
Displays standby voltage
Batt Volt. at
COMe Pin>
Read only field
Displays battery voltage at COMe pin
Widerange Vcc>
Read only field
Displays wide range VCC
Serial Port
Console
Redirection>
COM0
Console
Redirection>
Console redirection via COMe module’s COM1.
If redirection is enabled then the port settings such as Terminal type, Bits
per second, Data bits, Parity etc. can be adjusted here.
Note: on-module COM ports do not support flow control.
[Enabled, Disabled]
COM1
Console
Redirection>
Console redirection via COMe module’s COM2.
If redirection is enabled, then the port settings such as Terminal type, Bits
per second, Data bits, Parity etc. can be adjusted here.
Note: On-module COM ports do not support flow control.
[Enabled, Disabled]
COM0
Console
Redirection>
Console redirection via COM3, available with an optional Winbond SuperIO
on the baseboard. (Default is disabled)
If redirection is enabled, then the port settings such as Terminal type, Bits
per second, Data bits, Parity etc. can be adjusted here.’
[Enabled, Disabled]