D R A F T — F O R I N
T E R N A L U S E O N L Y
21
www.kontron.com
User Guide
CP3010-SA
Furthermore, boards with extended temperature range comply with the following standards as well.
1.6 Related Publications
The following publications contain information relating to this product.
Table 4: Additional Standards for Boards with Extended Temperature Range
TYPE
ASPECT
STANDARD
REMARKS
Thermal
Operating Low
Temperature
Railway TX
IEC 60068-2-1
Test Ad: Cold
Test parameters:
-40 [°C] ± 2 [°C]
16 [h] duration
1 cycle
1 [h] recovery (0.5 °C/min)
Operating High
Temperature
Railway TX
IEC 60068-2-2
Test Bd: Dry Heat
Test parameters:
+85[°C] ± 2[°C]
16 [h] duration
1 cycle
Environmental
Operating Vibration
Railway Category 1,
Class B
IEC 61000-2-64
Test Fh
Test parameters:
5-150 [Hz] frequency range
ASD Spectrum [(m/s²)²/f] intensity of random
vibration signal vs. frequency for X, Y, Z
1.00-0.45-0.70 [m/s²] rms
max. 10 [min] duration for each direction X, Y, Z
Operating Shocks
Railway Category 1,
Class B
IEC 60068-2-27
Test parameters:
30-30-50 [m/s²] acceleration x-y-z
30-30-50 [ms] recovery time x-y-z
3 shocks per direction (total: 18)
18 shocks
Table 5: Related Publications
PRODUCT
PUBLICATION
CompactPCI Systems
PICMG® 2.0, Rev. 3.0 CompactPCI® Specification
CFast
CFast Specification Revision 1.1
Platform Firmware
Unified Extensible Firmware Interface (uEFI) specification, version 2.3.1
All Kontron products
Product Safety and Implementation Guide, ID 1021-9142