266
394149/D
sensors and systems. To make sure that the information from the "most reliable" sensors
are used by the EK80, use the
Sensor Configuration
page to define a datagram priorities.
The communication parameters defined for NMEA 0183 are:
•
Baud rate
: 4800 bit/s
•
Data bits
: 8
•
Parity
: Even
•
Stop bits
: 1
Some instruments may provide other parameters and/or options. You must always check
the relevant technical documentation supplied by the manufacturer.
Procedure
1
Open the
Setup
menu.
2
On the
Setup
menu, select
Installation
.
Observe that the
Installation
dialog box opens. This dialog box contains a number
of pages selected from the menu on the left side.
3
On the left side of the
Installation
dialog box, select
Sensor Installation
.
a
Select the relevant sensor in the
Installed Sensors
list.
b
Make sure that the correct installation parameters are used for the sensor.
4
On the left side of the
Installation
dialog box, select
Sensor Configuration
.
a
Select the relevant sensor in the
Sensor
list.
b
Make sure that the correct parameters are used for sensor configuration.
5
Close the
Installation
dialog box without making any changes.
6
Observe the top bar.
7
Make sure that the information from the sensor is displayed.
If necessary, enable the read-out in the
Display Options
dialog box.
8
If possible, use another instrument to verify that the information provided by the
EK80 is correct.
9
Fill in the result tables.
Result
Sensor
Source sensor
Datagram
Port
Baud rate
Position
Speed
Distance
Heading
Simrad EK80 Installation Manual
Содержание Simrad EK80
Страница 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 12: ...10 394149 D Simrad EK80 ...
Страница 223: ...394149 D 221 6 Start the installation by selecting Next 7 Select Finish to close the wizard Setting to work ...
Страница 313: ...394149 D 311 Drawing file ...
Страница 314: ...312 394149 D Simrad EK80 Installation Manual ...
Страница 317: ...394149 D 315 Drawing file ...
Страница 318: ...316 394149 D Simrad EK80 Installation Manual ...
Страница 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Страница 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Страница 353: ......
Страница 354: ...Installation Manual Simrad EK80 ...