394149/D
159
Split beam transducer connection for single beam use on an
Amphenol socket
A split beam transducer can be connected to sockets
A
and
D
on a circular 12-pin
Amphenol transducer socket (Type 97-12-19S). This allows you to use the transducer as
a single beam unit.
The other end of the cable is permanently fixed to the
transducer.
The transducer is designed with the individual elements
organized in four separate sectors. It is very important
that the transducer is correctly installed with the sectors
positioned as shown in the illustration (seen from
above). Each sector is connected to a dedicated transceiver channel. In this context,
the phrase
transceiver channel
is used to describe one single pathway through the
transceiver. This pathway contains one transmitter, one preamplifier and the necessary
transmit/receive switching circuitry.
Note
We strongly recommend that you install the transducer cable in a steel conduit.
Depending on production date, the transducer can be delivered with two different cable
types. On older transducers the cable contains black and white conductors. On new
transducers the cable contains colour coded conductors.
Содержание Simrad EK80
Страница 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 12: ...10 394149 D Simrad EK80 ...
Страница 223: ...394149 D 221 6 Start the installation by selecting Next 7 Select Finish to close the wizard Setting to work ...
Страница 313: ...394149 D 311 Drawing file ...
Страница 314: ...312 394149 D Simrad EK80 Installation Manual ...
Страница 317: ...394149 D 315 Drawing file ...
Страница 318: ...316 394149 D Simrad EK80 Installation Manual ...
Страница 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Страница 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Страница 353: ......
Страница 354: ...Installation Manual Simrad EK80 ...