394149/D
151
Simrad TU40 interface to generic RS-232 synchronization
input
For transmission synchronization purposes, the Simrad TU40 will interface a generic
RS-232 serial line communication port using the CTS (Clear To Send) and RTS (Request
To Send) signals.
The NotUsed provides one output and one input for each hydroacoustic system that
needs to be synchronized. Each system is connected to the IO Module inside the
NotUsed. Each IO Module in the NotUsed comprises an analog input module, a digital
output module and a solid state relay module.
Pin
Signal
Trigger Unit
Signal description
Screen(Green)
Screen
A
Cable screen
Input
RTT
B
Ready to Transmit: Ready to
Transmit (RTT) is a return signal
from the hydroacoustic system that
is synchronized. The Ready to
Transmit (RTT) signal means that the
hydroacoustic system is ready for the
next trigger.
Ground
Ground
C
Signal ground
Output
Trigger Out
D
This signal is transmitted to the system
that needs to be synchronized. Trigger
Out allows the system to transmit
("ping").
Trigger Unit = Connections on the terminal block in the Trigger Unit
A
Local connection on the Processor Unit
B
Connections on the terminal block in the Trigger Unit (From left)
Содержание Simrad EK80
Страница 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 12: ...10 394149 D Simrad EK80 ...
Страница 223: ...394149 D 221 6 Start the installation by selecting Next 7 Select Finish to close the wizard Setting to work ...
Страница 313: ...394149 D 311 Drawing file ...
Страница 314: ...312 394149 D Simrad EK80 Installation Manual ...
Страница 317: ...394149 D 315 Drawing file ...
Страница 318: ...316 394149 D Simrad EK80 Installation Manual ...
Страница 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Страница 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Страница 353: ......
Страница 354: ...Installation Manual Simrad EK80 ...