142
394149/D
RS-422 serial line connection using five wires
An RS-422 serial line connection can transmit data at rates as high as 10 million bits per
second, and may be sent on cables as long as 1500 meters.
A
Local connection
B
Connection on remote device
For more information, refer to the end-user
documentation provided by the manufacturer.
C
Female 9-pin D-Subminiature connector
D
Male 9-pin D-Subminiature connector
Unless otherwise specified, this cable must be provided
by the installation shipyard.
Minimum cable requirements
•
Conductors
: 2 x 5 x 0.5 mm
2
•
Screen
: Overall braided
•
Voltage
: 60 V
•
Maximum outer diameter
: Defined by the plugs and/or the cable gland
If you wish to use RS-422 or RS-485 serial communication, use a cable with twisted
pairs. If you need to install a very long cable, increase the cross section.
Related topics
Cable drawings and specifications, page 136
About serial lines, page 164
Cable layout and interconnections, page 85
Simrad EK80 Installation Manual
Содержание Simrad EK80
Страница 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 12: ...10 394149 D Simrad EK80 ...
Страница 223: ...394149 D 221 6 Start the installation by selecting Next 7 Select Finish to close the wizard Setting to work ...
Страница 313: ...394149 D 311 Drawing file ...
Страница 314: ...312 394149 D Simrad EK80 Installation Manual ...
Страница 317: ...394149 D 315 Drawing file ...
Страница 318: ...316 394149 D Simrad EK80 Installation Manual ...
Страница 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Страница 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Страница 353: ......
Страница 354: ...Installation Manual Simrad EK80 ...