3.2 Explanation of components
Operation
3-86
WA500-6H – VEAM430100
Method of operation
Vent selection
The vents are all opened or closed manually.
A): Front vents (2 places)
(B): Foot vent (2 place)
(C): Defroster vents (4 places)
Cooling
1. Press ON/OFF switch (1) to turn on the air conditioner
power.
2. Press fan switch (2) to set the air flow to the maximum.
3. Press temperature control switch (3) to lower the tempera-
ture.
4. Press air conditioner switch (4) to set to COOLING.
5. Press RECIRC/FRESH selector switch (5) to set to
RECIRC.
6. When the temperature inside the cab goes down, set to the
desired temperature and air flow.
NOTE
z
If operations are continued for a long time with the air condi-
tioner set to the lowest temperature and minimum air flow,
there is danger that the receiver drier may freeze.
z
If it freezes and no cold air comes out, stop using the cool-
ing, and set to a higher temperature and the maximum air
flow. Run for a short time under these conditions, then
return.
Heating
1. Press ON/OFF switch (1) to turn on the air conditioner
power.
2. Press fan switch (2) to set the air flow to the maximum.
3. Press temperature control switch (3) to raise the tempera-
ture.
4. Press RECIRC/FRESH selector switch (4) to set to FRESH.
5. When the temperature inside the cab goes up, set to the
desired temperature and air flow.
REMARK
The heating uses the heat from the engine cooling water, so it is
effective only when the cooling water is hot.
GK050107
A
A
B
B
C
C
C
C
GK050108
1
3
4
5
2
GK050108
1
3
4
2
Содержание WA500-6H
Страница 2: ......
Страница 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Страница 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Страница 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Страница 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Страница 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Страница 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Страница 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Страница 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Страница 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Страница 408: ...Notes 8 2 WA500 6H VEAM430100...
Страница 409: ...Notes WA500 6H VEAM430100 8 3...
Страница 410: ...Notes 8 4 WA500 6H VEAM430100...
Страница 411: ...Notes WA500 6H VEAM430100 8 5...
Страница 412: ...Notes 8 6 WA500 6H VEAM430100...