4.9 Service procedure
Every 1000 hours service
Maintenance
4-74
WA500-6H – VEAM430100
Wash fuel tank breather
1. Stop the engine and wait for the temperature at all parts to
go down.
2. Remove all mud and dirt from around the breather.
3. Remove the breather and fit a cover to the breather mount-
ing hole to prevent dirt from entering.
4. Soak the breather in flushing liquid and wash it.
5. Install the breather.
Lubricating
1. Using a grease pump, pump in grease through the grease
fittings marked by the arrows.
2. After greasing, wipe off any old grease that was pushed out.
(1) Center hinge pin (2 places)
(2) Drive shaft center support (1 place)
GK050252
GK050253
1
1
GK050233
2
Содержание WA500-6H
Страница 2: ......
Страница 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Страница 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Страница 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Страница 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Страница 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Страница 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Страница 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Страница 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Страница 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Страница 408: ...Notes 8 2 WA500 6H VEAM430100...
Страница 409: ...Notes WA500 6H VEAM430100 8 3...
Страница 410: ...Notes 8 4 WA500 6H VEAM430100...
Страница 411: ...Notes WA500 6H VEAM430100 8 5...
Страница 412: ...Notes 8 6 WA500 6H VEAM430100...