6.1 Handling load meter
Attachments, Options
6-16
WA500-6H – VEAM430100
Calibration with empty bucket
1. Before carrying out calibration, set the machine in the follow-
ing condition.
Empty the bucket.
Carry out the warming-up operation.
Carry out warming up to set the hydraulic oil temperature to
the normal working range, then carry out normal operations
(including raising and lowering the lift arm) for at least 10
minutes (preferably more than 30 minutes).
2. Set so that the character display shows the normal service
meter and clock display.
3. Press the (
) portion of the character display mode selector
switch.
“LOAD METER“ is displayed on the top line of the character
display.
4. Use the (
) portion of the character display mode selector
switch and the (>) or (<) portion of the character display item
selector switch to display “CALIBRATION“ on the character
display.
1 9 . 0
h
0 3 : 0 9
GK050280
L O A D
M E T E R
>
<
GK050279
C A L I B R A T I O N
>
<
Содержание WA500-6H
Страница 2: ......
Страница 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Страница 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Страница 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Страница 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Страница 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Страница 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Страница 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Страница 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Страница 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Страница 408: ...Notes 8 2 WA500 6H VEAM430100...
Страница 409: ...Notes WA500 6H VEAM430100 8 3...
Страница 410: ...Notes 8 4 WA500 6H VEAM430100...
Страница 411: ...Notes WA500 6H VEAM430100 8 5...
Страница 412: ...Notes 8 6 WA500 6H VEAM430100...