REMARK
A fusible link is the large-sized fuse wiring installed in the high current flowing part of the circuit.
It protects electrical parts and wiring from burning out due to abnormal current, in the same way as an ordinary
fuse.
No.
Capaci-
ty
Name of circuit
Connector No.
(1)
45 A
Continuous power supply
M09
(2)
65 A
Standard power supply
M05
(3)
80 A
Preheat
TM14
(4)
60 A
Starting motor
TM15
TOOL BOX
Store the tools and warning tags in it.
It is located inside the cover under the operator's seat.
GREASE PUMP HOLDER
k
k
WARNING
Immediately after the engine is stopped, its parts and oil are still very hot and may cause burn injury.
Wait for the temperature to go down, and then start the work.
It is on the hydraulic tank.
Keep the grease pump hooked on the grease pump holder
while it is not used.
Close the handle of grease pump and keep it upward of the
machine to store it.
QUICK RELEASE BATTERY TERMINAL (-)
k
k
CAUTION
Before disconnecting the quick release battery terminal (-), be sure to remove the starting switch key.
If someone turns the key to ON position carelessly, this is extremely dangerous.
OPERATION
EXPLANATION OF COMPONENTS
3-85
WENAM00150
Содержание PC30MR-5
Страница 2: ......
Страница 66: ...WENAM00150 ...
Страница 69: ... 14 Engine rear cover 15 Cooling cover 16 Battery OPERATION GENERAL VIEW 3 3 WENAM00150 ...
Страница 257: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 WENAM00150 ...
Страница 324: ...The accumulator is installed to the position shown in the figure MAINTENANCE PROCEDURE MAINTENANCE 4 68 WENAM00150 ...
Страница 325: ...SPECIFICATIONS 5 1 WENAM00150 ...
Страница 363: ...REPLACEMENT PARTS 7 1 WENAM00150 ...
Страница 370: ...WENAM00150 ...
Страница 379: ......
Страница 380: ......