Function switch “F4”
Enters the change and returns the screen to “Breaker Setting” screen.
Function switch “F6”
Moves to the left letter.
When on the first letter, it moves to the last letter.
Function switch “F7”
Moves to the right letter.
When on the last letter, it moves to the first letter.
Function switch “F8”
If some input letter is left, “CLEAR” is displayed.
Clears all the letters.
If all the letters are cleared, “DEFAULT” is displayed.
Displays the initial name.
Changing “Breaker Oil Flow Rate Setting”
You can change the flow rate of each breaker setting to the arbitrary value.
1.
Select the breaker setting to change its flow rate on
“Breaker Setting” screen, and then press function switch
“F6”.
2.
The “Breaker Oil Flow Rate Setting” screen is displayed.
On “Breaker Oil Flow Rate Setting” screen, you can per-
form the following operations with function switches “F3”,
“F4”, “F6”, and “F7”.
Function switch “F3”
Returns the screen to “Breaker Setting” screen without
changing the flow rate.
Function switch “F4”
Enters the flow rate setting and returns the screen to
“Breaker Setting” screen.
Function switch “F6”
Decreases the flow rate by 1 level.
Function switch “F7”
Increases the flow rate by 1 level.
ATTACHMENT SETTING
For the machine(s) ready for installation of attachment, you can select the setting of ATT/P and ATT/E modes
from 5 patterns on “Attachment Setting” screen, or you can set it to “No Attachment”.
For each pattern on “Attachment Setting” screen, you can change its name displayed on the machine monitor.
For each pattern on “Attachment Setting” screen, you can adjust oil flow rate to the attachment corresponding to
the installed attachment.
For machines that have no attachment, “Attachment Setting”screen is not displayed.
OPERATION
EXPLANATION OF COMPONENTS
3-39
WENAM00150
Содержание PC30MR-5
Страница 2: ......
Страница 66: ...WENAM00150 ...
Страница 69: ... 14 Engine rear cover 15 Cooling cover 16 Battery OPERATION GENERAL VIEW 3 3 WENAM00150 ...
Страница 257: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 WENAM00150 ...
Страница 324: ...The accumulator is installed to the position shown in the figure MAINTENANCE PROCEDURE MAINTENANCE 4 68 WENAM00150 ...
Страница 325: ...SPECIFICATIONS 5 1 WENAM00150 ...
Страница 363: ...REPLACEMENT PARTS 7 1 WENAM00150 ...
Страница 370: ...WENAM00150 ...
Страница 379: ......
Страница 380: ......