1022476-2-
B
4
Kohler Co.
A
B
C
D
88” (223.5cm)
Verify that the subfloor offers adequate support, and is flat and level
Construct 2x4 or 2x6 stud framing according to the roughing--in information
Position the
rough plumbing
K-1687
K-1688
K-1689
A
46”
58”
34”
(116.8cm) (147.3cm) (86.5cm)
B
23”
29”
17”
(8.4cm)
(73.7cm)
(43.2cm)
C
35”
35”
35”
(88.9cm)
(88.9cm)
(88.9cm)
D
17-1/2”
17-1/2”
17-1/2”
(44.5cm)
(44.5cm)
(44.5cm)
If necessary, leave one of the framing side walls loose until you move the module into position
1. Construct the Framing
NOTICE:
Unless otherwise specified, floor support under the module must provide for a minimum of 80
lbs./square foot (390 Kg./square meter) loading.
NOTE:
Refer to the shower door installation instructions for any special framing considerations.
-
Make sure the flooring offers adequate support for your shower module, and verify that the subfloor is flat and
level.
-
Construct a 2x4 or 2x6 stud recess according to the roughing-in information packed. Provide double or triple stud
framing around the recess opening. Make sure the header is level and square.
-
If necessary, leave one of the stud recess walls loose until you move the module into position. Then line the recess
wall up with the module, and secure the recess wall permanently in place to the stud framing.
-
Add any bridging or support needed for extra grab bars or towel bars. Refer to the accessory manufacturer’s
instructions.
-
Measure and cut the drain hole opening in the floor, and install the rough drain lines. Install the rough plumbing.
Refer to the roughing-in information packed.
-
Stud opening tolerance is +1/4”, -0” (+6mm, -0mm). When a fire rated wall is specified, dimensions are to the
inside of the wallboard. Some shimming between the stud frame and fixture may be required.
Spec Seq#: 114
482971
Содержание K-3363
Страница 1: ...Spec Seq 72 S 1...
Страница 15: ...Spec Seq 81 S 2...
Страница 31: ...Spec Seq 90 WF 1...
Страница 49: ......
Страница 50: ...Spec Seq 94 MB 1...
Страница 52: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Страница 53: ...Spec Seq 96 189085...
Страница 54: ...Spec Seq 96 189085...
Страница 55: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Страница 58: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Страница 76: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Страница 94: ...Spec Seq 100 SH 1...
Страница 174: ...Spec Seq 112 SH 2...