3
Installation of Ceramic Cartridge
Step 1
Push each cartridge into valve
body until it seats. Add cap nuts and
hand tighten. Add handles.
Step 2
Rotate RIGHT handle (and
cartridge) counter clockwise to the
desired closed position.
Step 3
Using handle to maintain stem
position, fully tighten right cap nut to 20
to 27 ft. lb. torque.
Step 4
Move LEFT handle (without
moving cartridge) to the open position
and fully tighten right cap nut to 20 to
27 ft. lb. torque. Return handle to
closed position.
Note:
No replacement parts for ceramic cartridges,
sold only as complete assembly.
Ensure cartridges are in the closed
position before installing into valve body.
Cartridges feature color-coded seats.
Blue seat on cold cartridge, red seat on
hot cartridge.
Color-coded seat
Ceramic Operating Cartridges
Short Stem
No. 1-100XKJKNF
Left Hand Cartridge
No. 1-099XKJKNF
Right Hand Cartridge
Long Stem
No. 377-XKLHJKNF
Left Hand Cartridge
No. 377-XKRHJKNF
Right Hand Cartridge
Stem Identification
Spec Seq#: 98
361769
Содержание K-3363
Страница 1: ...Spec Seq 72 S 1...
Страница 15: ...Spec Seq 81 S 2...
Страница 31: ...Spec Seq 90 WF 1...
Страница 49: ......
Страница 50: ...Spec Seq 94 MB 1...
Страница 52: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Страница 53: ...Spec Seq 96 189085...
Страница 54: ...Spec Seq 96 189085...
Страница 55: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Страница 58: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Страница 76: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Страница 94: ...Spec Seq 100 SH 1...
Страница 174: ...Spec Seq 112 SH 2...