5-6
A-61662 April 2010
5. Remove the drive roller by placing your fingers on the left side of the
drive roller and push the roller as far right as possible. Hold it in
place. The spring-loaded drive roller shaft will move to the right side
of the scanner’s upper tray. Hold the driver roller shaft in place and
slide the drive roller off to the left and off the shaft. Gently release
the drive roller shaft back into position.
6. Using a cleaning wipe, scrub the drive roller tires in a side-to-side
motion. Rotate the roller to clean the entire surface of the tires.
7. Re-install the drive roller.
• With the drive roller positioned so the dots are facing the left side,
slide the roller onto the right drive roller shaft.
• Angle the right side of the drive roller onto the drive roller shaft
Push the roller onto the shaft and push the roller and shaft far
enough to the right so that the left side of the roller can be
positioned onto the left drive roller shaft.
• When the side of the drive roller is properly aligned onto the left
drive roller shaft, gently release the drive roller shaft back into
place.
8. Continue with cleaning the separator roller.
Driver roller in
Push
roller to
the right
far right position
Hold in place.
Hold shaft in
place to release
driver roller.