3-14
A-61662 April 2010
Maintenance button
When you click the
Maintenance
button on the Ngenuity Operator
Utility main screen, the Maintenance screen will be displayed.
This screen provides scanner statistics for total hours, total pages fed
and total pages scanned. The Maintenance screen also allows you to
configure reminders for different maintenance tasks that are required to
ensure optimal performance.
Scanner Stats
— this area provides statistics for
Total On Time
(awake and sleeping),
Total Pages
(fed) and total
Scanned Pages
.
These totals are updated every 2 seconds.
Configuration Maintenance Reminders
— allows you to set the
interval values for triggering the reminders that are visible in the
Maintenance section of the Home screen.
Intervals can be set for cleaning the feed rollers (skimmer rollers: pick
and drive and separator roller), the transport rollers, the optics and to
replace the feed rollers (skimmer rollers and separator roller). These
reminders can also be individually enabled and disabled. It is
recommended that you
do not
disable any of these reminders.
To enable and adjust a maintenance reminder, click the check box next
to the corresponding component and use the up/down arrows in the
Page Interval
column to change the value. Click
Save
to save your
changes or
Restore
to reset the values to the previously saved
settings.
The available interval settings and their defaults are:
Reminder
Range
Default
Clean Feed Rollers (skimmer rollers and separator roller)
1K - 50K
10K
Clean Transport Rollers
5K - 100K
50K
Clean Optics (camera covers, imaging guides, sensors)
5K - 150K
50K
Replace Feed Rollers (skimmer rollers and separator roller)
100K - 900K
600K