5-2
A-61662 April 2010
Maintenance
schedule
The following table is a recommended schedule for performing basic
maintenance functions. Some procedures may need to be performed
more frequently depending on your operating environment and the
types of documents being scanned.
Cleaning supplies
Scanner consumables and cleaning supplies are available from
resellers, web merchants and from the Kodak on-line store
(http:/scannerstore.kodak.com).
•
Ngenuity Roller Kit
•
Ngenuity Cleaning Kit including:
-
Blower brush
-
Transport cleaning sheets
-
Roller and glass cleaner
-
Lint-free cleaning cloths
-
Cleaning wipes
-
Swabs
Maintenance
Recommended
Range
Symptoms
Clean feed rollers: pick, drive,
and separator rollers
10,000 pages
1K - 50K
• Skewed documents
• Multifeeds
• Feeder jams
Clean transport rollers
50,000 pages
5K - 100K
• Multifeeds
• Transport jams
• Elongated images
Clean Optics: imaging guides,
cameras glass covers, sen-
sors.
Optics does not include
lamps
.
The lamps (LEDs)
should not be cleaned or
wiped with any type of wipe or
solvents.
50,000 pages
5K - 150K
Glass Camera Covers / Imaging Guides
• Streaks in the image
• Reduced OCR/ICR/Barcode recognition
rates
• Blurred images
Page Sensors
• Entry/exit sensor errors
Feeder Sensors
• Feeder table does not lower when out of
paper
Camera calibration
Every 1200 hours
N/A
Poor color image quality (e.g. white tinted
green, red or blue)
Replace feed rollers
600,000 pages
100K -
900K
• Noticeably worn rollers
• Page skewing, multifeeds and paper
jams continue to occur after cleaning is
performed
Ink cartridge(s) - only relevant
if optional imprinter(s)
installed
Approximately
34,000 pages (can
vary depending on
number of charac-
ters per page and
font used, etc.)
N/A
Poor print quality
Содержание Ngenuity 9090DB
Страница 1: ......
Страница 39: ...4 12 A 61662 April 2010 About screen The About screen displays the scanner version and copyright information...