• Pause Scanning - leave paper in path
: scanning will stop
immediately (i.e., making no attempt to clear the paper path) but the
scanning application will be waiting for additional images (i.e., stops
the feeder). Image(s) of the multifed document will not be generated.
Clear any documents from the paper path prior to resuming the scan
session. Scanning may be resumed by pressing the
Start/Resume
button on the scanner. Scanning may be stopped by pressing the
Stop/Pause
button on the scanner or via the scanning application.
The user configured multifeed sound will be made by the scanner.
• Pause Scanning - generate image(s)
: scanning will stop but the
scanning application will be waiting for additional images (i.e., stops
the feeder). Image(s) of the multifed document will be generated.
Scanning may be resumed by pressing the
Start/Resume
button on
the scanner. Scanning may be stopped by pressing the
Stop/Pause
button on the scanner or via the scanning application.
This option allows you to inspect a preview image of the scanned
page and choose to
Accept
the scanned image or
Rescan
the page
and discard the image from the scan that triggered a multifeed alarm.
The scanned images will not be sent to the host application until
accepted. This option allows all multifeed events to be handled at the
scanner. No image manipulation is required in the scanning
application. This option also allows you to stay in front of the scanner
reducing wasted movement and fatigue.
This option is provided by
the scanner. No changes to the scanning application are
required
.