31
www.kistlermorse.com
97-1129-01 Rev. D
lbs (pounds)
kg (kilograms)
CWT (hundred-weight)
tns (tons)
gal (gallons)
Ltr (liters)
bbl (barrels)
bu (bushels)
% (percent)
ft (feet)
m (meters)
mV (millivolts)
(none)
SCK
Follow this procedure to modify Disp units:
1. If the SVS2000 is in Run Mode, press the ‘1’ Key, ‘3’ Key, and Enter Key to access the menu tree. The
display shows:
13 DISP UnITS
2. Press the enter key to access this menu. The display looks like this:
unITS: *lbs
(Asterisk indicates the current selection.) If the displayed menu does not have the desired units, press
the Up Arrow Key to display the next page of the menu. Continue to press an Arrow Key until you see
the desired units (there are thirteen pages to the Disp Units Menu).
3. When the display shows the desired units, press the Enter Key. The display acknowledges the selection
and returns to:
13 DISP UnITS
4. Press an Arrow Key to scroll to another menu or press the Gross or net Key to return to Run Mode.
14 Bargraph Span
note: Bargraph Span was set by the SvS2000 based on your entries in Quick Config. In the Bargraph Span
Menu you can change the value. you can choose to view a numerical display or a bar graph of the gross weight
while in Run Mode. The maximum span for the bar graph is set with this menu. The bar graph displays the vessel
contents as a numerical percentage to the left of the graph, as shown below:
75%||||||||| |
The 0% point of the bar graph is always 0. The 100% point of the bar graph is set with the Bargraph Span. For
example, entering the vessel’s maximum capacity of 5000 lbs as the Bargraph Span results in a bar graph with
0% corresponding to 0 lbs and 100% corresponding to 5000 lbs. If the gross weight in the vessel falls outside
the range, the bargraph display does the following:
• gross weight falls below 0 (caused by inaccuracies in the calibration, vibration, drift, etc.) — The graph
remains at 0% and the numerical percentage remains at 0%.
• gross weight goes above the Bargraph Span value — The graph remains at 100% and the numerical
percentage reflects the actual weight. For example, if Bargraph Span is 5000 lbs and the gross weight is
7500 lbs, the numerical percentage displayed is 150% while the graph remains at 100%.
Содержание SVS2000
Страница 1: ...SVS2000 Installation Operation Manual IOM97 1129 01 Rev D...
Страница 2: ......
Страница 10: ...6 97 1129 01 Rev D www kistlermorse com...
Страница 11: ...7 www kistlermorse com 97 1129 01 Rev D...
Страница 12: ...8 97 1129 01 Rev D www kistlermorse com...
Страница 13: ...9 www kistlermorse com 97 1129 01 Rev D...
Страница 14: ...10 97 1129 01 Rev D www kistlermorse com...
Страница 20: ...16 97 1129 01 Rev D www kistlermorse com Figure 3 Wiring Diagram Current Output Card venture...