30
97-1129-01 Rev. D
www.kistlermorse.com
20, 50, 100, 200, 500, 1000, 5000, or 10000. A Disp Countby of 1 causes the rightmost active digit on the display
to change in increments of 1. A Disp Countby of 100 causes the rightmost three active digits on the display to
change in increments of 100. Use Disp Countby to adjust the display to a resolution consistent with the accuracy
of the system and reduce display flickering.
note that the selection for Disp Format affects how the SVS2000 interprets the Disp Countby value. Table 3
shows some examples of how these are related. example: For a 10,000 lb maximum weight and Disp Format
of xxxxxx, a Disp Countby of 1 is meaningful only if the system accuracy is ±0.01% of maximum load. A more
typical accuracy for a bolt-on strain gage application might be ±1%. Since 1% of 10,000 lbs is 100 lbs, a more
realistic DispCountby for this system is 100.
Table 3. Interaction of Format and Countby
Display Format
Disp Countby
Example Value
xxxx.xx
1
397.25
xxxx.xx
100
397.00
Xxxxxx
1
39725
Xxxxxx
100
39700
Xxxxxxoo
1
3972500
xxxxxxoo
100
3970000
Follow this procedure to modify
Disp Countby:
1. If the SVS2000 is in Run Mode, press the ‘1’ Key, ‘2’ Key, and Enter Key to access the menu tree. The
display shows:
12 DISP COunTBy
2. Press the enter key to access this menu. The display looks like this:
COunTBy: *1
(Asterisk indicates the current selection.) If the displayed menu does not have the desired countby, press
the Up Arrow Key to display the next page of the menu. Continue to press an Arrow Key until you see
the desired countby (there are twelve pages to the Disp Countby Menu).
3. When the display shows the desired countby, press the Enter Key. The display acknowledges the
selection and returns to:
12 DISP COunTBy
4. Press an Arrow Key to scroll to another menu or press the Gross or net Key to return to Run Mode.
13 dISp (dISplay) unITS
note: In Quick Config you selected lbs or kg as the unit of measure. In the Disp units menu you can choose from
a larger selection of units. However, if you change Disp Units you must also change other setup parameters.
See Modifying Disp Format and Disp Units in this chapter for details. This menu allows you to select the unit of
measure for the run mode. Listed below are the units available:
Содержание SVS2000
Страница 1: ...SVS2000 Installation Operation Manual IOM97 1129 01 Rev D...
Страница 2: ......
Страница 10: ...6 97 1129 01 Rev D www kistlermorse com...
Страница 11: ...7 www kistlermorse com 97 1129 01 Rev D...
Страница 12: ...8 97 1129 01 Rev D www kistlermorse com...
Страница 13: ...9 www kistlermorse com 97 1129 01 Rev D...
Страница 14: ...10 97 1129 01 Rev D www kistlermorse com...
Страница 20: ...16 97 1129 01 Rev D www kistlermorse com Figure 3 Wiring Diagram Current Output Card venture...