Calibra on Problems:
Here are some examples of common calibra on problems.
In this display, one sensor is flashing. This shows that the sensor is voted out. If it comes back
within range, it will be voted back in, stop flashing and return to green.
A failed sensor is a different situa on. In this case, the sensor failed calibra on. Changing the
sensor won't make it register again. Once a sensor has failed calibra on, the only way to bring
it back is to successfully calibrate. If the computer were to display a value with a new sensor, it
would be a meaningless value without calibra on.
This display indicates a faulty sensor. It is not within the normal range for a sensor in oxygen.
Most sensors are designed to output 10 mV +/‐ 3 mV in air. If the output is linear, then that
translates to a range of 30 to 70 as valid mV readings in 98% oxygen. The computer will refuse
to calibrate outside that range.
Three sensors all showing FAIL is usually caused by an accidental calibra on in air, or a calibra‐
on with the cable unplugged. Plugging the cable back in won't change anything. Failed cali‐
bra ons can only be fixed by successful calibra ons.