Pre-Dive
© MMXXI Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 210902001
17
3. The KMDSI mouthpiece P/N 810-022L must fit snug completely around
the mounting tube regardless of its shape.
The final test prior to installation should be that the KMDSI mouthpiece
should remain on the mounting tube after a simple test of a slight pull
when secured without a tie wrap.
Do not stretch the pod mouthpiece opening greater than 50%.
Failure to use the correct type of demand regulator will result in flood-
ing of the pod, which can lead to drowning. If in doubt do not install the
regulator until first consulting with KMDSI or Dive Lab Inc.
Some manufacturers have specially shaped mouthpiece mounting tubes
that have mating mouthpieces. These types of regulators cannot be used.
There must be a retaining lip at the end of the mouthpiece mounting tube
of your regulator in order to retain the mouthpiece. Use the included
mouthpiece to check the mount tube compatibility.
The mouthpiece mount tube
must have sufficient surface
area to retain the mouthpiece to
the tube.
This type
NOT
acceptable
This type
OK
Mouthpiece mounting tube (shown in magnified view).
The KMDSI mouthpiece and pod opening can be safely stretched to 50%.
Do not use regulators that have a mouthpiece tube that have a double lip
at the end of the tube closest to your mouth, as illustrated at the above.
A pull test (see page 22) should be performed to confirm proper at-
tachment of the regulator to the POD and mouthpiece
.