3
VISION 2460 INSTALL GUIDE
Technical Specifications
Operating Voltage:
Current Consumption:
Operating Temp.:
Certification:
Control Module
Siren
24Vdc
7.1mA
(Average, Armed w/ LED flashing)
5.8mA
(Average, Disarmed)
(Does not include Sensor or Siren consumption. See below.)
-40°C to +85°C
IP40
Operating Voltage:
Current Consumption:
Operating Temp.:
Loudness:
Audio Generator:
Housing:
Certification:
Replacement P/N:
24Vdc
5.5mA
(trickle charge)
, 1A
(during full siren blast)
-40°C to +125°C
125dB
(measured 30cm/1ft from speaker)
1-tone
(6-tone selectable by cutting loop on siren)
Water-resistant
(cannot be submerged)
IP54
KB24-1
Shock Sensor
Operating Voltage:
Current Consumption:
Operating Temp.:
Sensor Technology:
Certification:
Replacement P/N:
12Vdc
(supplied by 2460 Control Module)
Adds 2.5mA
(avg.)
to Control Module Current Con-
sumption when Armed, 0mA when Disarmed
-40°C to +85°C
Infra-red Beam Deflection
IP40
(durability tested to IP50)
318-052
2460B
2460B