6
VISION 2460 INSTALL GUIDE
SYSTEM WIRING DIAGRAM
2460B
3-wire Harness
4-wire Harness
4-wire Sensor Harness
RED
BLK
Optional
Remote*
* Connector for the Antenna Unit of the optional TR537S 2-way Paging Remote or TR365 1-Way Remote.
When adding an optional remote, you must learn the remote to the 2460. Refer to the User Guide that comes
with the TR537S or TR365 for details.
1
Output is typically used to control optional LED scanners (LUMINATOR).
2
Some trucks require use of the optional DSS-6 wire splitter to easily connect to multiple locations.
3
Some trucks require the use of an optional relay to invert the polarity of this wire to (+)24v.
4
Peak output (only for short duration use of several minutes) is 900mA. Excessive current draw above 1A will
cause the output voltage to fall and possibly shut off the 2460 until the high current load is removed. When
powering 12V devices for many hours continuously while driving, please limit the average current consump-
tion to approximately 300mA or less to keep the power supply running cool.
5A
Fuse
ORG
YEL
(–) GWA Output
1
(0.7A)
BLK
(–) System Ground
WHT
(–) Door Input
2
RED
GRN/WHT
(+)24v System Power
(+)24v Ignition Input
(–) Horn/Siren Output (1A)
LED
Program
Switch
Program
Switch
LED
6-wire Main Harness
Shock
Sensor
VISION
IR SHOC
K SENSOR
GRN
YEL/BLK
(–) Starter Kill Output (0.7A)
(–) Parking Light Output
(1A)
PUR
(+)12v Power Output
4
(0.3A)
WHT/RED
BLU/YEL
(+)24v Door UNLOCK input
GRN/YEL
(+)24v Door LOCK input
(+)24v Hazard Light Input
(–) Back Door Input
WHT/BLK
ALWAYS tape/cover all wires that
you do not use. Prevent shorts!