PBZ
147
5
Ext
ernal Co
ntrol, Pa
rallel
Operation, an
d Synchronizat
ion
Synchronization Feature
By using the synchronization feature, you can:
•
Turn the output of multiple units on and off at the same time.
•
Synchronize sequence start timing across multiple units.
•
Synchronize the clocks of multiple PBZs.
Output on/off synchronization and sequence start timing synchronization can be used at the
same time as clock synchronization.
Connection Procedure
Connect coaxial cables to the rear panel TRIG IN and TRIG OUT terminals.
•
Up to five slave units can be connected to the master unit’s TRIG OUT terminal (see
connection example 1).
•
You can connect slave units to other slave units (see connection example 2).
•
You can connect any unit from the PBZ series (PBZ20-20 and PBZ40-10).
•
Even if the master unit, slave units, and slave end units are operating in parallel, you can
connect them for synchronization (by using the TRIG IN and TRIG OUT terminals of the
master unit that is operating in parallel).
See
TRIG IN
TRIG OUT
1
2
TRIG IN
TRIG OUT
(SYNC OUT)
TRIG OUT
(SYNC OUT)
TRIG OUT
TRIG IN
(SYNC IN)
TRIG IN
(SYNC IN)
TRIG IN
TRIG OUT
(SYNC OUT)
TRIG IN
(SYNC IN)
TRIG OUT
TRIG IN
(SYNC IN)
TRIG OUT
TRIG IN
(SYNC IN)
TRIG OUT
Connection example
External
device
External device
External device
External device
External
device
External
device
SYNC MASTER
SYNC SLAVE (END)
SYNC MASTER
SYNC SLAVE
SYNC SLAVE (END)
SYNC SLAVE (END)
SYNC SLAVE (END)
Содержание PBZ20-20
Страница 11: ...PBZ 11 ...
Страница 18: ...18 PBZ ...
Страница 75: ...Memory Response and Configuration This chapter explains preset memory setup memory response and configura tion ...
Страница 95: ...Sequences This chapter explains sequences ...
Страница 153: ...Maintenance This chapter describes how to clean and inspect the PBZ ...
Страница 156: ...156 PBZ Maintenance ...
Страница 157: ...Appendix A List of Factory Default Settings B Troubleshooting C List of Error Messages D Options ...