112
PBZ
Executing Programs
Program execution flowchart
•
Press RUN/PAUSE or STOP to make the PBZ enter the program execution (SEQ
EXECUTION) state.
•
Specify a program number and execute it (press RUN/PAUSE).
•
If you press RUN/PAUSE while a program is executing, the execution is paused.
•
If the program is designed to wait for a trigger signal, it enters the WAIT state.
•
When a program completes, the PBZ enters the COMPLETED state.
•
Press ENTER.
The PBZ returns to the state where you can set the DC signal (as if you had pressed the
DC key).
•
To abort execution, press STOP or OUTPUT. If you press OUTPUT, regardless of the
programmed output settings, the output is turned off.
•
If an alarm is generated, the PBZ enters the ALARM state.
■
If a protection feature is activated during program execution
If OVP, OCP, or OHP is activated during program execution, an alarm is generated.
■
Setting the protection features during program execution
You can set the protection features during program execution.
■
Setting the measurement feature during program execution
You can set the measurement feature during program execution.
TRIG IN: ON
TRIG IN
RUN
RUN/PAUSE
STOP
RUN/PAUSE
ENTER
ENTER
ALM CLR
ALM CLR
STOP
OUTPUT
SEQ EXECUTION
COMPLETED
RUN
PAUSE
WAIT
ABORT
Start
End
ALARM
ALARM
END
ALARM
ALARM
RUN/PAUSE
RUN/PAUSE
See
See
See
Содержание PBZ20-20
Страница 11: ...PBZ 11 ...
Страница 18: ...18 PBZ ...
Страница 75: ...Memory Response and Configuration This chapter explains preset memory setup memory response and configura tion ...
Страница 95: ...Sequences This chapter explains sequences ...
Страница 153: ...Maintenance This chapter describes how to clean and inspect the PBZ ...
Страница 156: ...156 PBZ Maintenance ...
Страница 157: ...Appendix A List of Factory Default Settings B Troubleshooting C List of Error Messages D Options ...