Step Settings
4
Se
quences
●
Summary of the practical example
■
DC RAMP: OFF, AMPL SWEEP: ON, FREQ SWEEP: OFF
To make the DC signal jump to its specified value immediately and sweep the AC signal
amplitude
●
Summary of the practical example
Item
At the beginning of step execution
At the end of step execution
DC signal
value
DC signal start value
Because DC RAMP is set to ON, when the
step execution time finishes, the DC signal
is at the specified DC setting.
AC signal
amplitude
Because SWEEP is set to OFF, AMPL
is set to the AMPL setting when the
step execution begins.
The AC signal amplitude that the PBZ
was set to when the previous step
completed execution does not
continue into this step.
Because SWEEP is set to OFF, AMPL
remains at the same AMPL setting (that it
was set to when step execution began)
from the start to the end of step execution.
The AC signal amplitude that the PBZ is
set to when this step completes execution
does not continue into the next step.
AC signal
start phase
angle
Because PHASE is set to FREE, the
start phase angle is indeterminate.
Regardless of the PHASE setting, the
phase angle is indeterminate.
Item
At the beginning of step execution
At the end of step execution
DC signal
value
Because DC RAMP is set to OFF,
when the step execution time starts,
the DC signal is at the specified DC
setting.
Because DC RAMP is set to OFF, the DC
value remains at the same DC setting
(that it was set to when step execution
began) from the start to the end of step
execution.
AC signal
amplitude
Because SWEEP is set to ON, the
amplitude is set to the START setting
when the step execution begins.
The AC signal amplitude that the PBZ
was set to when the previous step
completed execution does not
continue into this step.
Because SWEEP is set to ON, the
amplitude is set to the STOP setting when
the step execution begins.
The AC signal amplitude that the PBZ is
set to when this step completes execution
does not continue into the next step.
AC signal
start phase
angle
PHASE is set to 90
.
Regardless of the PHASE setting, the
phase angle is indeterminate.
Step execution time
Step 1
Step 2
DC
AMPL
SWEEP
STOP
AMPL =
AMPL
SWEEP
START
PHASE
FREQ
FUNC
TIME
1
2
4
3
5
6
7
4
3
7
7
1
2
5
6
Содержание PBZ20-20
Страница 11: ...PBZ 11 ...
Страница 18: ...18 PBZ ...
Страница 75: ...Memory Response and Configuration This chapter explains preset memory setup memory response and configura tion ...
Страница 95: ...Sequences This chapter explains sequences ...
Страница 153: ...Maintenance This chapter describes how to clean and inspect the PBZ ...
Страница 156: ...156 PBZ Maintenance ...
Страница 157: ...Appendix A List of Factory Default Settings B Troubleshooting C List of Error Messages D Options ...