Step Settings
4
Se
quences
●
OUTPUT (output on and off)
•
ON: The output is turned on.
•
OFF: The output is turned off.
●
TRIG OUT (trigger signal output)
•
ON: A trigger signal is generated when step execution
time begins.
•
OFF: Trigger signals are not generated.
You can select the output trigger signal polarity (rising or falling). Use
to select the
slope.
●
TRIG IN (trigger signal input)
Use TRIG IN to set the PBZ’s
response to trigger signal input.
•
ON: The PBZ waits for a trigger
signal to be applied when step
execution time begins (the PBZ
enters the WAIT state).
•
OFF: Trigger signals are not
detected.
The trigger signal input type is level
trigger. You can set the level polarity to either H (high) or L (low). Use
to select the
level.
The time to switch the output from off to on or from on to off is added to the step execution
time.
Step n - 1
Step number
Step n
Step n + 1
OUTPUT setting
Output state
OUTPUT setting
Output state
ON
ON
OFF
OFF
OFF
ON
ON
Time required to switch the output state
40.1 ms
40 ms
Open
Open
ON
TIME setting
TIME setting
TIME setting
TRIG OUT
Step n
Step n + 1
(Polarity set to rising)
See
CONFIG
Step n - 1
Step n
Step n + 1
WAIT
TRIG IN
Trigger input
signal
OFF
ON
(Polarity set to H level)
CONFIG
Содержание PBZ20-20
Страница 11: ...PBZ 11 ...
Страница 18: ...18 PBZ ...
Страница 75: ...Memory Response and Configuration This chapter explains preset memory setup memory response and configura tion ...
Страница 95: ...Sequences This chapter explains sequences ...
Страница 153: ...Maintenance This chapter describes how to clean and inspect the PBZ ...
Страница 156: ...156 PBZ Maintenance ...
Страница 157: ...Appendix A List of Factory Default Settings B Troubleshooting C List of Error Messages D Options ...