132
PBZ
Program Examples
Example 5: Performing a Ramp Transition That Takes Lon-
ger than 1000 Seconds
This example shows the settings that you can use to perform a DC signal ramp transition or
an AC signal amplitude sweep so that they exceed the length of time given in the
specifications (1000 seconds).
■
DC RAMP: ON, AMPL SWEEP: OFF, FREQ SWEEP: OFF
Performing a DC signal ramp transition from 0 V to 12 V over 1 hour (3600 seconds)
1
Divide the total ramp transition into a series of steps so that each step is
1000 seconds or less and the total execution time adds up to 3600
seconds.
2
Set the start value of each step to the end value of the previous step to
make the steps continuous.
1 800 s
2 700 s
3 600 s
0 s
900 s
STEP1
TIME:
0H15M00s0000
DC RAMP: ON
START: 0.000 V
STOP: 3.000 V
STEP2
TIME:
0H15M00s0000
DC RAMP: ON
START: 3.000 V
STOP: 6.000 V
STEP3
TIME:
0H15M00s0000
DC RAMP: ON
START: 6.000 V
STOP: 9.000 V
STEP4
TIME:
0H15M00s0000
DC RAMP: ON
START: 9.000 V
STOP: 12.000 V
0 V
3 V 3 V
6 V 6 V
9 V
9 V
12 V