Overview of Messages
Default Conditions
Conditions after sending a *RST and at power-on
Table shows how the PAT-T is set when the *RST command is executed, at the time of
factory shipment, and when the power is turned on.
Setup item
Setting
Unit Function
*RST
Factory
default
At power-on
OUTP
0/OFF
0/OFF
0/OFF
*1
--
Output on/off
setting.
OUTP:PON:STAT
RST
*2
RST
*2
Setting immediately
before turning the
POWER switch off
--
Output condition at
power-on.
OUTP:EXT
NORM
NORM
--
Logical setting of
the output on/off
using external
contact.
VOLT
0
0
V
Voltage setting.
VOLT:EXT:SOUR
NONE
*3
NONE
*3
--
Control mode
setting of constant
voltage.
VOLT:FINE
*7
0
0
--
Fine adjustment
setting for voltage.
VOLT:LIM:AUTO
0/OFF
0/OFF
--
Voltage limit
setting.
VOLT:PROT
111.5 % of the
rated output
voltage
V
OVP setting.
VOLT:TRIG
0
0
V
Target voltage
using a trigger.
CURR
105.0 % of the
rated output
current
A
Current setting.
CURR:EXT:SOUR
NONE
*3
NONE
*3
--
Control mode
setting of constant
current.
CURR:FINE
*7
0
0
--
Fine adjustment
setting for current.
CURR:LIM:AUTO
0/OFF
0/OFF
--
Current limit
setting.
CURR:PROT
111.5 % of the
rated output
current
A
OCP setting.
CURR:TRIG
105.0 % of the
rated output
current
A
Target current
using a trigger.
OUTP:TRIG
0/OFF
0/OFF
--
Setting of whether
to turn the output
on/off using a
trigger.
TRIG:SOUR
BUS
*4
BUS
*4
BUS
*4
--
Sequence 1 trigger
source.